{"product_id":"eaton-moeller-series-nzm-molded-case-circuit-breakernzmn3ve400400amp","title":"Eaton Moeller series NZM  Molded Case Circuit BreakerNZMN3VE400400amp","description":"\u003cp\u003e**SEE PICTURES FOR ITEM CONDITION**\u003c\/p\u003e\u003cbr\u003e\u003cbr\u003e\u003cp\u003eGENERAL SPECIFICATIONS\u003c\/p\u003e\u003cbr\u003e\u003cp\u003ePRODUCT NAME\u003c\/p\u003e\u003cp\u003eEaton Moeller series NZM - Molded Case Circuit Breaker\u003c\/p\u003e\u003cp\u003eCATALOG NUMBER\u003c\/p\u003e\u003cp\u003e168506\u003c\/p\u003e\u003cp\u003eMODEL CODE\u003c\/p\u003e\u003cp\u003eNZMN3-4-VE400-SVE\u003c\/p\u003e\u003cp\u003eEAN\u003c\/p\u003e\u003cp\u003e4015081650255\u003c\/p\u003e\u003cp\u003ePRODUCT LENGTH\/DEPTH\u003c\/p\u003e\u003cp\u003e335 mm\u003c\/p\u003e\u003cp\u003ePRODUCT HEIGHT\u003c\/p\u003e\u003cp\u003e215.2 mm\u003c\/p\u003e\u003cp\u003ePRODUCT WIDTH\u003c\/p\u003e\u003cp\u003e185 mm\u003c\/p\u003e\u003cp\u003ePRODUCT WEIGHT\u003c\/p\u003e\u003cp\u003e10.04 kg\u003c\/p\u003e\u003cp\u003eCOMPLIANCES\u003c\/p\u003e\u003cp\u003eRoHS conform\u003c\/p\u003e\u003cp\u003eCERTIFICATIONS\u003c\/p\u003e\u003cp\u003eIEC\/EN 60947 \u003c\/p\u003e\u003cp\u003eIEC\u003c\/p\u003e\u003cp\u003ePRODUCT SPECIFICATIONS\u003c\/p\u003e\u003cbr\u003e\u003cp\u003eRATED OPERATIONAL CURRENT FOR SPECIFIED HEAT DISSIPATION (IN)\u003c\/p\u003e\u003cp\u003e400 A\u003c\/p\u003e\u003cp\u003e10.11 SHORT-CIRCUIT RATING\u003c\/p\u003e\u003cp\u003eIs the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/p\u003e\u003cp\u003eRATED SHORT-CIRCUIT BREAKING CAPACITY ICS (IEC\/EN 60947) AT 690 V, 50\/60 HZ\u003c\/p\u003e\u003cp\u003e5 kA\u003c\/p\u003e\u003cp\u003e10.4 CLEARANCES AND CREEPAGE DISTANCES\u003c\/p\u003e\u003cp\u003eMeets the product standard's requirements.\u003c\/p\u003e\u003cp\u003e10.12 ELECTROMAGNETIC COMPATIBILITY\u003c\/p\u003e\u003cp\u003eIs the panel builder's responsibility. The specifications for the switchgear must be observed.\u003c\/p\u003e\u003cp\u003eMOUNTING METHOD\u003c\/p\u003e\u003cp\u003eBuilt-in device plug-in technique \u003c\/p\u003e\u003cp\u003ePlug-in unit\u003c\/p\u003e\u003cp\u003eAMPERAGE RATING\u003c\/p\u003e\u003cp\u003e400 A\u003c\/p\u003e\u003cp\u003e10.2.5 LIFTING\u003c\/p\u003e\u003cp\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/p\u003e\u003cp\u003eTERMINAL CAPACITY (COPPER STRIP)\u003c\/p\u003e\u003cp\u003e10 segments of 50 mm x 1 mm (2x) at rear-side width extension \u003c\/p\u003e\u003cp\u003eMax. 8 segments of 24 mm x 1 mm (2x) at box terminal \u003c\/p\u003e\u003cp\u003eMax. 10 segments of 32 mm x 1 mm + 5 segments of 32 mm x 1 mm at rear-side connection (punched) \u003c\/p\u003e\u003cp\u003eMax. 10 segments of 24 mm x 1 mm + 5 segments of 24 mm x 1 mm \u003c\/p\u003e\u003cp\u003eMin. 6 segments of 16 mm x 0.8 mm at rear-side connection (punched) \u003c\/p\u003e\u003cp\u003eMin. 6 segments of 16 mm x 0.8 mm at box terminal\u003c\/p\u003e\u003cp\u003eHANDLE TYPE\u003c\/p\u003e\u003cp\u003eRocker lever\u003c\/p\u003e\u003cp\u003e10.2.3.1 VERIFICATION OF THERMAL STABILITY OF ENCLOSURES\u003c\/p\u003e\u003cp\u003eMeets the product standard's requirements.\u003c\/p\u003e\u003cp\u003eAMBIENT STORAGE TEMPERATURE - MIN\u003c\/p\u003e\u003cp\u003e40 °C\u003c\/p\u003e\u003cp\u003ePROTECTION AGAINST DIRECT CONTACT\u003c\/p\u003e\u003cp\u003eFinger and back-of-hand proof to DIN EN 50274\/VDE 0106 part 110\u003c\/p\u003e\u003cp\u003eTERMINAL CAPACITY (COPPER BUSBAR)\u003c\/p\u003e\u003cp\u003eMax. 30 mm x 10 mm + 30 mm x 5 mm direct at switch rear-side connection \u003c\/p\u003e\u003cp\u003eMin. 20 mm x 5 mm direct at switch rear-side connection \u003c\/p\u003e\u003cp\u003eMax. 10 mm x 50 mm (2x) at rear-side width extension \u003c\/p\u003e\u003cp\u003eM10 at rear-side screw connection\u003c\/p\u003e\u003cp\u003e10.8 CONNECTIONS FOR EXTERNAL CONDUCTORS\u003c\/p\u003e\u003cp\u003eIs the panel builder's responsibility.\u003c\/p\u003e\u003cp\u003eSPECIAL FEATURES\u003c\/p\u003e\u003cp\u003eMaximum back-up fuse, if the expected short-circuit currents at the installation location exceed the switching capacity of the circuit breaker (Rated short-circuit breaking capacity Icn) R.m.s. value measurement and “thermal memory” Adjustable time delay setting to overcome current peaks tr at 6 x Ir also infinity (without overload releases) Adjustable delay time tsd Rated current = rated uninterrupted current: 400 A Terminal capacity hint: Up to 240 mm² can be connected depending on the cable manufacturer.\u003c\/p\u003e\u003cp\u003eAMBIENT OPERATING TEMPERATURE - MAX\u003c\/p\u003e\u003cp\u003e70 °C\u003c\/p\u003e\u003cp\u003ePOSITION OF CONNECTION FOR MAIN CURRENT CIRCUIT\u003c\/p\u003e\u003cp\u003eFront side\u003c\/p\u003e\u003cp\u003eCURRENT RATING OF NEUTRAL CONDUCTOR\u003c\/p\u003e\u003cp\u003e200% of phase conductor\u003c\/p\u003e\u003cp\u003eCLIMATIC PROOFING\u003c\/p\u003e\u003cp\u003eDamp heat, cyclic, to IEC 60068-2-30 \u003c\/p\u003e\u003cp\u003eDamp heat, constant, to IEC 60068-2-78\u003c\/p\u003e\u003cp\u003eTERMINAL CAPACITY (COPPER STRANDED CONDUCTOR\/CABLE)\u003c\/p\u003e\u003cp\u003e25 mm² - 240 mm² (1x) direct at switch rear-side connection \u003c\/p\u003e\u003cp\u003e35 mm² - 240 mm² (1x) at box terminal \u003c\/p\u003e\u003cp\u003e16 mm² - 185 mm² (1x) at 1-hole tunnel terminal \u003c\/p\u003e\u003cp\u003e25 mm² - 240 mm² (2x) direct at switch rear-side connection \u003c\/p\u003e\u003cp\u003e25 mm² - 120 mm² (2x) at box terminal\u003c\/p\u003e\u003cp\u003eFEATURES\u003c\/p\u003e\u003cp\u003eProtection unit \u003c\/p\u003e\u003cp\u003eMotor drive optional\u003c\/p\u003e\u003cp\u003eLIFESPAN, ELECTRICAL\u003c\/p\u003e\u003cp\u003e5000 operations at 400 V AC-1 \u003c\/p\u003e\u003cp\u003e3000 operations at 690 V AC-1 \u003c\/p\u003e\u003cp\u003e2000 operations at 415 V AC-3 \u003c\/p\u003e\u003cp\u003e2000 operations at 690 V AC-3 \u003c\/p\u003e\u003cp\u003e2000 operations at 400 V AC-3 \u003c\/p\u003e\u003cp\u003e5000 operations at 415 V AC-1\u003c\/p\u003e\u003cp\u003eELECTRICAL CONNECTION TYPE OF MAIN CIRCUIT\u003c\/p\u003e\u003cp\u003eScrew connection\u003c\/p\u003e\u003cp\u003eSHORT-CIRCUIT TOTAL BREAKTIME\u003c\/p\u003e\u003cp\u003e\u0026lt; 10 ms\u003c\/p\u003e\u003cp\u003eRATED IMPULSE WITHSTAND VOLTAGE (UIMP) AT MAIN CONTACTS\u003c\/p\u003e\u003cp\u003e8000 V\u003c\/p\u003e\u003cp\u003eRATED SHORT-CIRCUIT BREAKING CAPACITY ICS (IEC\/EN 60947) AT 400\/415 V, 50\/60 HZ\u003c\/p\u003e\u003cp\u003e50 kA\u003c\/p\u003e\u003cp\u003e10.9.3 IMPULSE WITHSTAND VOLTAGE\u003c\/p\u003e\u003cp\u003eIs the panel builder's responsibility.\u003c\/p\u003e\u003cp\u003eUTILIZATION CATEGORY\u003c\/p\u003e\u003cp\u003eA (IEC\/EN 60947-2)\u003c\/p\u003e\u003cp\u003eNUMBER OF POLES\u003c\/p\u003e\u003cp\u003eFour-pole\u003c\/p\u003e\u003cp\u003eAMBIENT OPERATING TEMPERATURE - MIN\u003c\/p\u003e\u003cp\u003e-25 °C\u003c\/p\u003e\u003cp\u003e10.6 INCORPORATION OF SWITCHING DEVICES AND COMPONENTS\u003c\/p\u003e\u003cp\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/p\u003e\u003cp\u003e10.5 PROTECTION AGAINST ELECTRIC SHOCK\u003c\/p\u003e\u003cp\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/p\u003e\u003cp\u003eTERMINAL CAPACITY (CONTROL CABLE)\u003c\/p\u003e\u003cp\u003e0.75 mm² - 2.5 mm² (1x) \u003c\/p\u003e\u003cp\u003e0.75 mm² - 1.5 mm² (2x)\u003c\/p\u003e\u003cp\u003eEQUIPMENT HEAT DISSIPATION, CURRENT-DEPENDENT\u003c\/p\u003e\u003cp\u003e72 W\u003c\/p\u003e\u003cp\u003eINSTANTANEOUS CURRENT SETTING (II) - MIN\u003c\/p\u003e\u003cp\u003e800 A\u003c\/p\u003e\u003cp\u003e10.13 MECHANICAL FUNCTION\u003c\/p\u003e\u003cp\u003eThe device meets the requirements, provided the information in the instruction leaflet (IL) is observed.\u003c\/p\u003e\u003cp\u003e10.2.6 MECHANICAL IMPACT\u003c\/p\u003e\u003cp\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/p\u003e\u003cp\u003e10.9.4 TESTING OF ENCLOSURES MADE OF INSULATING MATERIAL\u003c\/p\u003e\u003cp\u003eIs the panel builder's responsibility.\u003c\/p\u003e\u003cp\u003eRATED SHORT-CIRCUIT BREAKING CAPACITY ICS (IEC\/EN 60947) AT 230 V, 50\/60 HZ\u003c\/p\u003e\u003cp\u003e85 kA\u003c\/p\u003e\u003cp\u003eAPPLICATION\u003c\/p\u003e\u003cp\u003eUse in unearthed supply systems at 690 V\u003c\/p\u003e\u003cp\u003e10.3 DEGREE OF PROTECTION OF ASSEMBLIES\u003c\/p\u003e\u003cp\u003eDoes not apply, since the entire switchgear needs to be evaluated.\u003c\/p\u003e\u003cp\u003eRATED SHORT-CIRCUIT MAKING CAPACITY ICM AT 240 V, 50\/60 HZ\u003c\/p\u003e\u003cp\u003e187 kA\u003c\/p\u003e\u003cp\u003eRATED SHORT-CIRCUIT BREAKING CAPACITY ICS (IEC\/EN 60947) AT 440 V, 50\/60 HZ\u003c\/p\u003e\u003cp\u003e35 kA\u003c\/p\u003e\u003cp\u003eDEGREE OF PROTECTION (IP), FRONT SIDE\u003c\/p\u003e\u003cp\u003eIP40 (with insulating surround) \u003c\/p\u003e\u003cp\u003eIP66 (with door coupling rotary handle)\u003c\/p\u003e\u003cp\u003eRATED SHORT-CIRCUIT MAKING CAPACITY ICM AT 525 V, 50\/60 HZ\u003c\/p\u003e\u003cp\u003e53 kA\u003c\/p\u003e\u003cp\u003eRATED SHORT-CIRCUIT MAKING CAPACITY ICM AT 690 V, 50\/60 HZ\u003c\/p\u003e\u003cp\u003e40 kA\u003c\/p\u003e\u003cp\u003eINSTANTANEOUS CURRENT SETTING (II) - MAX\u003c\/p\u003e\u003cp\u003e4400 A\u003c\/p\u003e\u003cp\u003eOVERLOAD CURRENT SETTING (IR) - MIN\u003c\/p\u003e\u003cp\u003e200 A\u003c\/p\u003e\u003cp\u003eSHORT DELAY CURRENT SETTING (ISD) - MIN\u003c\/p\u003e\u003cp\u003e400 A\u003c\/p\u003e\u003cp\u003eNUMBER OF AUXILIARY CONTACTS (NORMALLY CLOSED CONTACTS)\u003c\/p\u003e\u003cp\u003e0\u003c\/p\u003e\u003cp\u003e10.2.3.2 VERIFICATION OF RESISTANCE OF INSULATING MATERIALS TO NORMAL HEAT\u003c\/p\u003e\u003cp\u003eMeets the product standard's requirements.\u003c\/p\u003e\u003cp\u003e10.2.3.3 RESIST. OF INSUL. MAT. TO ABNORMAL HEAT\/FIRE BY INTERNAL ELECT. EFFECTS\u003c\/p\u003e\u003cp\u003eMeets the product standard's requirements.\u003c\/p\u003e\u003cp\u003eLIFESPAN, MECHANICAL\u003c\/p\u003e\u003cp\u003e15000 operations\u003c\/p\u003e\u003cp\u003eOVERLOAD CURRENT SETTING (IR) - MAX\u003c\/p\u003e\u003cp\u003e400 A\u003c\/p\u003e\u003cp\u003eVOLTAGE RATING\u003c\/p\u003e\u003cp\u003e690 V - 690 V\u003c\/p\u003e\u003cp\u003eTERMINAL CAPACITY (COPPER SOLID CONDUCTOR\/CABLE)\u003c\/p\u003e\u003cp\u003e16 mm² (2x) at box terminal \u003c\/p\u003e\u003cp\u003e16 mm² (1x) at tunnel terminal \u003c\/p\u003e\u003cp\u003e16 mm² (2x) direct at switch rear-side connection \u003c\/p\u003e\u003cp\u003e300 mm² (2x) at rear-side width extension \u003c\/p\u003e\u003cp\u003e16 mm² (1x) direct at switch rear-side connection\u003c\/p\u003e\u003cp\u003eDEGREE OF PROTECTION (TERMINATIONS)\u003c\/p\u003e\u003cp\u003eIP00 (terminations, phase isolator and strip terminal) \u003c\/p\u003e\u003cp\u003eIP10 (tunnel terminal)\u003c\/p\u003e\u003cp\u003eTERMINAL CAPACITY (ALUMINUM STRANDED CONDUCTOR\/CABLE)\u003c\/p\u003e\u003cp\u003e50 mm² - 240 mm² (2x) at 2-hole tunnel terminal \u003c\/p\u003e\u003cp\u003e50 mm² - 240 mm² (1x) at 2-hole tunnel terminal \u003c\/p\u003e\u003cp\u003e25 mm² - 185 mm² (1x) at tunnel terminal\u003c\/p\u003e\u003cp\u003e10.9.2 POWER-FREQUENCY ELECTRIC STRENGTH\u003c\/p\u003e\u003cp\u003eIs the panel builder's responsibility.\u003c\/p\u003e\u003cp\u003eDEGREE OF PROTECTION\u003c\/p\u003e\u003cp\u003eIP20 (basic degree of protection, in the operating controls area) \u003c\/p\u003e\u003cp\u003eIP20\u003c\/p\u003e\u003cp\u003eOVERVOLTAGE CATEGORY\u003c\/p\u003e\u003cp\u003eIII\u003c\/p\u003e\u003cp\u003eRATED SHORT-TIME WITHSTAND CURRENT (T = 1 S)\u003c\/p\u003e\u003cp\u003e3.3 kA\u003c\/p\u003e\u003cp\u003eSHORT DELAY CURRENT SETTING (ISD) - MAX\u003c\/p\u003e\u003cp\u003e4000 A\u003c\/p\u003e\u003cp\u003eRATED IMPULSE WITHSTAND VOLTAGE (UIMP) AT AUXILIARY CONTACTS\u003c\/p\u003e\u003cp\u003e6000 V\u003c\/p\u003e\u003cp\u003eNUMBER OF AUXILIARY CONTACTS (CHANGE-OVER CONTACTS)\u003c\/p\u003e\u003cp\u003e0\u003c\/p\u003e\u003cp\u003eRATED SHORT-TIME WITHSTAND CURRENT (T = 0.3 S)\u003c\/p\u003e\u003cp\u003e3.3 kA\u003c\/p\u003e\u003cp\u003eACCESSORIES REQUIRED\u003c\/p\u003e\u003cp\u003eNZM3-XSVS\u003c\/p\u003e\u003cp\u003eAMBIENT STORAGE TEMPERATURE - MAX\u003c\/p\u003e\u003cp\u003e70 °C\u003c\/p\u003e\u003cp\u003eRELEASE SYSTEM\u003c\/p\u003e\u003cp\u003eElectronic release\u003c\/p\u003e\u003cp\u003eRATED SHORT-CIRCUIT BREAKING CAPACITY ICS (IEC\/EN 60947) AT 525 V, 50\/60 HZ\u003c\/p\u003e\u003cp\u003e13 kA\u003c\/p\u003e\u003cp\u003eOPTIONAL TERMINALS\u003c\/p\u003e\u003cp\u003eBox terminal. Connection on rear. Tunnel terminal\u003c\/p\u003e\u003cp\u003ePOLLUTION DEGREE\u003c\/p\u003e\u003cp\u003e3\u003c\/p\u003e\u003cp\u003e10.7 INTERNAL ELECTRICAL CIRCUITS AND CONNECTIONS\u003c\/p\u003e\u003cp\u003eIs the panel builder's responsibility.\u003c\/p\u003e\u003cp\u003e10.10 TEMPERATURE RISE\u003c\/p\u003e\u003cp\u003eThe panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.\u003c\/p\u003e\u003cp\u003eFUNCTIONS\u003c\/p\u003e\u003cp\u003eSystems, cable, selectivity and generator protection\u003c\/p\u003e\u003cp\u003eRATED SHORT-CIRCUIT MAKING CAPACITY ICM AT 400\/415 V, 50\/60 HZ\u003c\/p\u003e\u003cp\u003e105 kA\u003c\/p\u003e\u003cp\u003eSTANDARD TERMINALS\u003c\/p\u003e\u003cp\u003eScrew terminal\u003c\/p\u003e\u003cp\u003eTYPE\u003c\/p\u003e\u003cp\u003eCircuit breaker\u003c\/p\u003e\u003cp\u003e10.2.2 CORROSION RESISTANCE\u003c\/p\u003e\u003cp\u003eMeets the product standard's requirements.\u003c\/p\u003e\u003cp\u003e10.2.4 RESISTANCE TO ULTRA-VIOLET (UV) RADIATION\u003c\/p\u003e\u003cp\u003eMeets the product standard's requirements.\u003c\/p\u003e\u003cp\u003e10.2.7 INSCRIPTIONS\u003c\/p\u003e\u003cp\u003eMeets the product standard's requirements.\u003c\/p\u003e\u003cp\u003eRATED SHORT-CIRCUIT MAKING CAPACITY ICM AT 440 V, 50\/60 HZ\u003c\/p\u003e\u003cp\u003e74 kA\u003c\/p\u003e\u003cp\u003eNUMBER OF AUXILIARY CONTACTS (NORMALLY OPEN CONTACTS)\u003c\/p\u003e\u003cp\u003e0\u003c\/p\u003e\u003cp\u003eISOLATION\u003c\/p\u003e\u003cp\u003e300 V AC (between the auxiliary contacts) \u003c\/p\u003e\u003cp\u003e500 V AC (between auxiliary contacts and main contacts)\u003c\/p\u003e\u003cp\u003eNUMBER OF OPERATIONS PER HOUR - MAX\u003c\/p\u003e\u003cp\u003e60\u003c\/p\u003e\u003cp\u003eCIRCUIT BREAKER FRAME TYPE\u003c\/p\u003e\u003cp\u003eNZM3\u003c\/p\u003e\u003cp\u003eDIRECTION OF INCOMING SUPPLY\u003c\/p\u003e\u003cp\u003eAs required\u003c\/p\u003e\u003cp\u003eSHOCK RESISTANCE\u003c\/p\u003e\u003cp\u003e20 g (half-sinusoidal shock 20 ms)\u003c\/p\u003e\u003cp\u003eTERMINAL CAPACITY (ALUMINUM SOLID CONDUCTOR\/CABLE)\u003c\/p\u003e\u003cp\u003e16 mm² (1x) at tunnel terminal\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":45874870878364,"sku":"NZN3N3-VE400","price":1499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0602\/9053\/1484\/files\/57_6f17404e-f963-48b8-a7c5-12c3630b5de6.jpg?v=1767170379","url":"https:\/\/energypowersystemsllc.com\/products\/eaton-moeller-series-nzm-molded-case-circuit-breakernzmn3ve400400amp","provider":"Energy Power Systems LLC","version":"1.0","type":"link"}