{"product_id":"eaton-dg225nrk-400a-240v-2-pole-fusible-safety-switch-nema-3r-w-neutral-series","title":"Eaton DG225NRK 400A 240V 2-Pole Fusible Safety Switch NEMA 3R w\/ Neutral Series","description":"\u003cdiv style=\"font-family:Arial,Helvetica,sans-serif;color:#222;max-width:900px;margin:auto;line-height:1.45\"\u003e\n\u003ch1 style=\"font-size:22px;color:#1f3b63\"\u003eEaton DG225NRK 400A 240V 2-Pole Fusible Safety Switch with Neutral, NEMA 3R, General Duty\u003c\/h1\u003e\n\u003cp\u003eEaton general-duty 400 amp, 240 volt, two-pole three-wire fusible safety switch with neutral in a NEMA 3R rainproof enclosure. Takes Class H fuses as standard. With Class R fusing it is rated 100 kA. AL\/CU terminals.\u003c\/p\u003e\n\u003ch2 style=\"color:#1f3b63;border-bottom:2px solid #1f3b63;padding-bottom:4px\"\u003eWhat the part number means\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;margin:8px 0 16px\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #999;padding:6px;background:#1f3b63;color:#fff;text-align:left\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"border:1px solid #999;padding:6px;background:#1f3b63;color:#fff;text-align:left\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eDG\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eGeneral-duty, cartridge fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eTwo-pole (two blades)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003e2\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003e240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003e5\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003e400 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eN\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eFusible with neutral (3-wire, S\/N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eR\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eNEMA 3R rainproof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eK\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eSeries K design (general duty 200 A and up)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2 style=\"color:#1f3b63;border-bottom:2px solid #1f3b63;padding-bottom:4px\"\u003eSpecifications \u0026amp; features\u003c\/h2\u003e\n\u003ctable style=\"border-collapse:collapse;width:100%;font-size:14px;margin:8px 0 16px\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"border:1px solid #999;padding:6px;background:#1f3b63;color:#fff;text-align:left\"\u003eItem\u003c\/th\u003e\n\u003cth style=\"border:1px solid #999;padding:6px;background:#1f3b63;color:#fff;text-align:left\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eCatalog number\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eDG225NRK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eUPC\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003e782113589503\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eGeneral-duty fusible safety switch, single-throw, 2-pole 3-wire with solid neutral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eRating\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003e400 A, 240 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eMax HP (dual-element fuses)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003e3-phase 240V: 50â€“125 HP (grounded B-phase rating); 250 Vdc: 50 HP; single-phase: not rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eFuse provision\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eClass H fuse clips standard. Class R adapter kit sold separately (DS56FK, UNCONFIRMED)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eShort-circuit rating\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003e10,000 A rms sym with Class H fuses; 100 kA at 250V with Class R\/J\/T fusing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eLine\/load lugs\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003e(2) #1\/0â€“300 kcmil or (1) #1\/0â€“750 kcmil per phase, CU\/AL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eGround lug\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003e(2) #6â€“250 kcmil CU\/AL, factory installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eEnclosure\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eNEMA 3R, painted galvanized steel, bolt-on hub provision, side-opening door\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eFeatures\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eVisible blades, quick-make\/quick-break, cover interlocked when ON, triple padlocking, clearly visible handle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eDimensions \/ weight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003e44.74 H x 23.08 W x 7.27 D in, 120 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eUL Listed File E5239, UL 98, NEMA KS-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eService entrance\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eSuitable only with neutral kit (catalog note). Neutral kit for 400 A DG is DS400NK.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eSeries \/ date\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #999;padding:6px;vertical-align:top\"\u003eSeries B per label, date 06\/20\/2022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003cp style=\"background:#fff4e5;border-left:4px solid #e69500;padding:8px\"\u003e\u003cb\u003eFuses not included.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch2 style=\"color:#1f3b63;border-bottom:2px solid #1f3b63;padding-bottom:4px\"\u003eCondition\u003c\/h2\u003e\n\u003cp\u003eNew, open box. Interior clean, hardware bag included. Date 06\/20\/2022. Series B. Qty 1.\u003c\/p\u003e\n\u003ch2 style=\"color:#1f3b63;border-bottom:2px solid #1f3b63;padding-bottom:4px\"\u003eShipping\u003c\/h2\u003e\n\u003cp\u003eShips by free flat-rate freight (approx. 150 lb packed, 48 x 26 x 10 in). No local pickup.\u003c\/p\u003e\n\u003cp style=\"font-size:12px;color:#666\"\u003eSpecs are from Eaton catalogs and product pages for this catalog number. Please check the nameplate photos against your application.\u003c\/p\u003e\n\u003c\/div\u003e\n","brand":"Eaton","offers":[{"title":"Default Title","offer_id":48299398660252,"sku":"DG225NRK","price":1495.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0602\/9053\/1484\/files\/57_c33d0937-1fe3-4da8-9ad3-5ec083037a92.jpg?v=1794195396","url":"https:\/\/energypowersystemsllc.com\/products\/eaton-dg225nrk-400a-240v-2-pole-fusible-safety-switch-nema-3r-w-neutral-series","provider":"Energy Power Systems LLC","version":"1.0","type":"link"}